Instrumentação Analítica para ETE (Estação de Tratamento de Esgoto e Efluentes Industriais)
|
INSTRUMENTAÇÃO ANALÍTICA PARA ETE (ESTAÇÃO DE TRATAMENTO DE ESGOTO E EFLUENTES INDUSTRIAIS)
|
|

informações
didáticas sobre esta família de produtos
|

|
Consulte nosso especialista Nascimento

suporte p/ esta família de produtos
|
|
|
|
Analisador de Nível de Manto de Lodo MTS7210
Modell MTS 7210 consists of:
Turbidity sensor (submersion type): Model 7510 SAM-T-S (absorption of light) for solid concentration measurement
Microprocessor controlled transmitter with 2 outputs for
Stepping motor drive and cable drum for moving the sensor
Plastic cabinet with integrated heater
|
manto_lodo.pdf
|
|
|
|
|
Analisador de Sólidos em Suspensão 7110 MTF-FG
The Model 7110 MTF-FG is a continuous on-line transmitter that measures suspended solids concentration or turbidity.
It can display measurements in various units (ppm, mg/l, g/l, %, NTU or FTU), depending on the sensor model being used.
|
Solidos_Susp.pdf
|
|
|
|
|
Analisador de Oxigênio Dissolvido Hobeco OOM223
Universal application
Switchable between oxygen concentration in mg/l and saturation index in % SAT via software switching
Simple handling
Logically arranged menu structure with plain text in 6 languages facilitates instrument configuration
Large, two-line display indicates measured value and temperature at the same time
Ultrasimple one-point calibration in air or in the medium
Safe operation
Overvoltage (lightning) protection according to EN 61000-4-5
Direct access for manual contact control
|
Transmissor_O2.pdf
|
|
|
|
|
Sensor de Oxigênio Disolvido OOS4
Areas of application
The continuous measurement of the
dissolved oxygen concentration in water
plays an important role in many areas of
water economy:
Measurement of O content in 2
activated sludge basins. Here, the
measuring signal is used for
monitoring and as a control parameter.
2
Checking the O content in sewage
treatment plant effluent
Monitoring of public waters, e.g.
rivers, lakes and sea
Measurement and control of O2
content in fish ponds and fresh or salt
water fishfarming
Water treatment, e.g. oxygen
enrichment of drinking water.
|
Oxigenio_Dissolvido_OOS4.pdf
Oxigenio_Diss_Montagem.PDF
IET_cos61.pdf
|
|
|
|
|
On-line ammonium measurement GENION 1 (NH4)
GENION 1 is an on-line analyzer for continuous NH4 measurement in difficult wastewater applications, using a gas-selective electrode. The analyzer automatically calibrates itself daily using a standard.
|
STIP Genion 1 NH4_HBS.pdf
|
|
|
|
|
On-line ammonium measurement GENION 3 (NH4)
GENION 3 is an on-line analyzer for continuous NH4 measurement, using a gas-selective probe. The overall measurement range is 0.1 - 50 mg/liter NH4, while the spread of measurable concentrations is 1:50. The concentration spread is defined by the calibration standards. The analyzer automatically calibrates itself daily using two standards.
|
STIP Genion 3 NH4_HBS.pdf
|
|
|
|
|
On-line ammonium and nitrate measurement GENION 4(NH4/NO3)
GENION 4 is an on-line analyzer for simultaneous and continuous NH4 and NO3 measurement in wastewater. The NH4 measurement is a gas selective probe, while the NO3 measurement is ion selective. The overall measurement ranges are 0.1 - 50 mg/liter NH4, and 0.1 - 1000 mg/liter NO3 while the spread of measurable concentrations is 1:50. The concentration spread is defined by the calibration standards. The analyzer automatically calibrates itself daily using two standards.
|
STIP Genion 4 NH4 & NO3_HBS.pdf
|
|
|
|
|
On-line nitrate measurement GENION 5 (NO3)
GENION 5 is an on-line analyzer for continuous NO3 measurement in wastewater. Measurement is via an ion selective probe. The overall measurement range is 0.1 - 1000 mg/liter NO3 while the spread of measurable concentrations is 1:50. The concentration spread is defined by the calibration standards. The analyzer automatically calibrates itself daily using two standards.
|
STIP Genion 5 NO3_HBS.pdf
|
|
|
|
|
Continuous rapid COD measurement PHOENIX-1010
Continuous rapid COD measurement is a procedure for quick analysis of Chemical Oxygen Demand. In PHOENIX-1010, this procedure uses ozone for oxidation and thus operates with one of the most powerful oxidizing agents available. The analysis lag time between sample entering the intake and data output is 3 to 15 minutes for a measurement range of 10 to 1500 mg/liter COD. The analyzer automatically calibrates itself each day.
|
STIP Phoenix 1010 COD_HBS.pdf
|
|
|
|
|
Continuous rapid COD measurement PHOENIX-1010
Continuous rapid COD measurement is a procedure for quick analysis of Chemical Oxygen Demand. In PHOENIX-1010, this procedure uses ozone for oxidation and thus operates with one of the most powerful oxidizing agents available. The analysis lag time between sample entering the intake and data output is 3 to 15 minutes for a measurement range of 10 to 1500 mg/liter COD. The analyzer automatically calibrates itself each day.
|
STIP Phoenix 1010 COD_HBS.pdf
|
|
|
|
|
Spectrophotometric Analyzer SPECTRON (S)
SPECTRON (S) is a spectrophotometric on-line analyzer that can be adapted for user-specified applications. The analyzer incorporates a diode array spectrophotometer for measurement at wavelengths from 380 to 780 mm. Measurement is quasi-continuous. SPECTRON (S) can be equipped per user choice with one or two reagent pumps, and with different configurations to measure for example nitrite, cobalt, or phenol. The technical data include description and data for the nitrite parameter. The analyzer automatically calibrates itself daily using two standards.
|
STIP Spectron (s)_HBS.pdf
|
|
|
|
|
Nitrate/Ammonium measurement (Spectrophotometric/gas selective) SPECTRON (NO3/NH4)
SPECTRON (NO3/NH4) is a spectrophotometric analyzer for simultaneous measurement of nitrate and ammonium in wastewater. Nitrate measurement is quasi-continuous and performed photometrically, while the ammonium measurement is gas selective and continuous. The analyzer automatically calibrates itself daily using two standards.
|
STIP Spectron NO3 & NH4_HBS.pdf
|
|
|
|
|
Nitrate measurement (Spectrophotometric) SPECTRON (NO3)
SPECTRON (NO3 ) is a spectrophotometric analyzer for quasicontinuous measurement of nitrate in wastewater. A specific reagent is added, which forms an intense yellow complex with nitrate with concentration-dependent absorbance between 380 and 500 nm. The analyzer is equipped with a diode-array spectrophotometer that operates from 380 to 780 nm, and automatically calibrates itself daily using two standards.
|
STIP Spectron NO3_HBS.pdf
|
|
|
|
|
Phosphate/Ammonium measurement (Spectrophotometric/gas selective) SPECTRON (PO4/NH4)
SPECTRON (PO4/NH4) is an online analyzer for simultaneous measurement of phosphate and ammonium in wastewater. Phosphate measurement is quasicontinuous and performed photometrically, while the ammonium measurement is gas selective and continuous. The analyzer automatically calibrates itself daily using two standards.
|
STIP Spectron PO4 & NH4_HBS.pdf
|
|
|
|
|
Phosphate/Nitrate measurement (Spectrophotometric/ion selective) SPECTRON (PO4/NO3)
SPECTRON (PO4/NO3) is an online analyzer for simultaneous measurement of phosphate and nitrate in wastewater. Phosphate measurement is quasi-continuous and performed photometrically, while the nitrate measurement is ion selective and continuous. The analyzer automatically calibrates itself daily using two standards.
|
STIP Spectron PO4 & NO3_HBS.pdf
|
|
|
|
|
Phosphate measurement (Spectrophotometric, green method) SPECTRON (PO4 green)
SPECTRON (PO4 green) is a spectrophotometric analyzer for quasicontinuous measurement of phosphate in wastewater having yellow-colored interferences. Specific reagents are added, which form an intense blue-green complex with phosphorus with concentration- dependent absorbance between 600 and 730 nm. The analyzer is equipped with a diodearray spectrophotometer that operates from 380 to 780 nm, and automatically calibrates itself daily using two standards.
|
STIP Spectron PO4 green_HBS.pdf
|
|
|
gn="left"> UnitedWater Report.pdf
OnlineMeasurementforWaterToxicity.pdf
IWA publication_Gahr.pdf
|